UltimaSerial WinDaq Add-on:  Alarm 
Data logger
UltimaSerial

 

Windaq add-ons
Windaq Add-ons

 

Spectrogram
UltimaWaterfall

 

Ultimaserial XChart
XChart

 

FFT1024
FFT1024

 

Ultimaserial Classroom
Lessons

 

Alarm (ID=7020)

Obsolete, please use Alarm II instead. Due to its status, it is normally installed as a hidden add-on. Please use Windaq Add-on Manager to add it to Windaq's menu if you wish to use it

A great utility to provide closed-loop control based on readings from Windaq. 

Windaq Add-on Alarm for WinDaq running DATAQ devices, Transonic Flow meters and Dataforth isoLynx SLX718

  • Support various combination of alarms 

  • All settings are retainable 

  • Both digital and visual alarm outputs

  • Monitoring rate up to 60Hz, depending on OS and workload

  • Conditions can be changed on the fly

  • Channel number is a 0-based index to Windaq's scanlist. For example, if Windaq has channel 3,4,6,7 enabled, one can enter 0 for channel 3, 1 for channel 4, 2 for channel 6 and 3 for channel 7. You may also set the channel to

    • None so that this alarm indicator will stay unchanged 

    • ALL so that the alarm will be triggered when ALL channels meet the condition (see above)

    • ANY so that the alarm will be triggered when any one of the enabled channels meets the condition (see above)

  • Please configure the corresponding DIOs on DI-71x to outputs if you wish to use the digital outputs with DI-71x (Latest Windaq and DATAQ activex installation is required)

  • Due to the limitations of the hardware, when using with 720/730 USBs, please make sure Windaq's maximum sample rate doesn't exceed 100K, and the sample rate is less than 50K

  • Bonus for users with paid registration :

    • No ad-line nor time limit 

To Use WinDaq Add-ons

  1. Confirm WinDaq 3.16 or higher is installed on your computer

  2. Install WinDaq add-ons.

  3. Start WinDaq, and you will find the WinDaq add-ons integrated into Windaq->View->Add-ons menu (see the screen capture above).

  4. Intelligent Channel Selection: Highlight/Select a channel in WinDaq and fire up the WinDaq add-on you wish, and the WinDaq add-on will use the selected channel as its default channel. 

  5. If channel index number is required for a WinDaq add-on, please enter the 0-based index to Windaq's scanlist. For example, if WinDaq has channel 3,4,6,7 enabled, one can enter 0 for channel 3, 1 for channel 4, 2 for channel 6 and 3 for channel 7.

  6. Do not change WinDaq's configurations while WinDaq add-ons are running, or some add-ons may terminate.

 

Last update: 11/02/11