UltimaSerial WinDaq Add-on Update Logs
 

Windaq add-ons

 

 
June 1, 2010 WinDaq add-on is released through CNET.COM to minimize traffic to our ISP
July 12, 2010 Event Counter is added
Aug 12, 2010 Calculated Channel Recorder is added
Sept 1, 2010 Increase the number of calculated channel to 16 for Calculated Channel Recorder 
Sept 7, 2010 FFT Viewer for WWB is added
Oct 1, 2010 Calculated Trigger Recorder is added
Oct 7, 2010 Add Trigger Status to Calculated Trigger Recorder
Fixed the error message "Run Time Error 13, Type mismatch" when WinDaq throughput rate is higher than 10000 s/s while the PC's license is lower that Full Corporate License.
Oct 13, 2010:

Magic Meter is added

Nov 2, 2010  Instrumentation Gauge is added
Both Magic Meter and Gauge now support math involving data-window results, for example,  #rms0*0.3
Nov 10, 2010

Instrumentation Gauge and Magic Meter's last location will be retained

Nov 20, 2010 WinDaq add-on will not quit when WinDaq changes its configuration. 
Dec 1, 2010

WinDaq Excel Link supports both 32-bit and 64-bit Excel

Dec 8, 2010 MagicMeter, Gauge, Calculated DAC output and Alarm II support non-English (United States) Regional and Language options. 

Since other calculated add-ons require more computing powers, instead of allowing non-English (United States) Regional and Language options, it will warn users and ask for modification if period is not the decimal mark.

Jan 7, 2011 Fixed following bugs:

1) Gauge does not display correct unit 
2) Gauge may be placed outside of the screen if it was terminated from minimized state previously

Feb 16, 2011 Remove some restrictions for unregistered users, such as copy-and-paste function
March 24, 2011 Dynamometer is added
March 28, 2011 Allow sign selection for torque shaft rotation in dyno recorder. Supports Torque Display 6400 and 3410
March 31, 2011 Added Excel direct link to Manual NoteTaker, Remote Event Note Taker and Paced Note Taker
April 1, 2011 Users without administrator right can retain Windaq Add-on settings
April 15, 2011 Added instrument configuration for Dynamometer recorder
May 18, 2011 Added Logarithmic Frequency Scaling to FFT II
Added advanced calculated channel to Alarm II
Remove the maximize button for Alarm II to prevent resizing error 
May 24, 2011

 (version 1.56)
Better post-error handling for math equation option under MagicMeter and Gauge
Alarm II is available for DI-148/158 
June 7, 2011

(version 1.58)
Min/Max retainers is added to Gauge
Fixed math error in adds involving calculated channels. The glitch happens when result is very near zero
Sept 20, 2011
(version 1.65)
Support DI-149's extra features
New cross hair features (via right mouse button) for FFT II and Spectrogram II 
Spectrogram uses actual (averaged) update interval to calculate elapsed time for cross-hair
Alarm II supports Force Reset and Force Set options
Alarm II can access digital input via #dig
Oct 4, 2011

(version 1.67)

Fixed the polling interval of Alarm II, which was accidentally set to 1Hz in previous release
Digital Output II is added. 

Nov 1, 2011

(version 1.72)

 

Remove obsolete add-ons to make room for new add-ons
GUI improvement for Calculated Channel
AuxInputIndicator is added
Digital Plot is added
Keyboard operation is added to Digital Output II
D7 error is fixed on Digital Output II
Global Key option is added to Digital Output II
Nov 21, 2011

(version 1.73)

Global Key option is added to WinDaq Manual Note Taker
Dec 12, 2011

(version 1.86)

Advanced Triggered Storage is added

Added to Event Counter are: Math module, Analog trigger and WinDaq link

Added to Remote Note Taker are Analog trigger

Jan 24, 2012

(version 1.95)

GUI improvement for FFT II, Spectrogram II, DigitalOutput II, Gauge, Calculated Analog Output and MagicMeter

Feb 14, 2012

(version 1.99)

GUI improvement for Calculated Waveform, PacedNoteTaker

Better error handling for Calculated Channel Recorder II

Feb 28, 2012

(version 2.02)

Calculated Analog Trigger with Excel Link   is released

WinDaq Add-on Batch Operation  is released.

Paced Note Taker with Excel Link allows timers to go higher than 60 seconds, up to 32000 seconds

March 2, 2012

(version 2.03)

Allows FFT II and Spectrogram II to remove DC component before performing FFT

(version 2.14)

Email/Text Messaging (SMS)-enabled data acquisition, or Email link for WinDaq add-ons

Integration function added to Calculated Channel Recorder II

Digital Output II is renamed to Digital and Alarm Output

Email/SMS-option added to Digital and Alarm Output and Remote Event Note Taker

Fixed the error: Digital and Alarm Output failed to retain its slider settings

 

 

Last update: 05/03/12

© www.ultimaserial.com